A1C Calculator & Blood Glucose Unit Converter

Estimate your A1C, convert blood sugar units, and convert A1C to average glucose

Frequently Asked Questions

mmol/L = mg/dL ÷ 18.0182. This conversion factor comes from glucose's molar mass (about 180.16 g/mol) — the US and a few other countries report blood glucose in mg/dL, while most of the world (UK, Canada, Europe) uses mmol/L.
mg/dL = mmol/L × 18.0182. For example, a reading of 7.0 mmol/L converts to about 126 mg/dL.
Using the ADAG study formula solved for A1C: A1C (%) = (average glucose in mg/dL + 46.7) ÷ 28.7. For example, an average glucose of 154 mg/dL corresponds to an estimated A1C of about 7.0%. This is the reverse of the eAG formula below.
eAG (estimated Average Glucose) translates your A1C percentage into the same mg/dL or mmol/L units as a glucose meter, using the ADAG study formula: eAG (mg/dL) = 28.7 × A1C − 46.7. It gives a rough sense of what your daily meter readings have averaged over the past ~3 months.
No — eAG is a 2-3 month average derived from A1C, not a real-time reading. Day-to-day glucose swings (highs after meals, lows between them) can vary widely around this average, so eAG and a single meter reading measure different things.
For a fasting glucose reading, the ADA's published ranges are: normal below 100 mg/dL (5.6 mmol/L), prediabetes 100-125 mg/dL (5.6-6.9 mmol/L), and diabetes 126 mg/dL (7.0 mmol/L) or above. For A1C: normal below 5.7%, prediabetes 5.7-6.4%, and diabetes 6.5% or above. These are general reference ranges, not a diagnosis — only a doctor can interpret your specific result in context.
IFCC (mmol/mol) is the international laboratory standard unit for A1C, used in most countries outside the US instead of the NGSP % most US labs report. IFCC = (A1C% − 2.15) × 10.929 — for example, an A1C of 7.0% converts to about 53 mmol/mol IFCC.
GMI (Glucose Management Indicator) is a separate formula developed specifically for continuous glucose monitor (CGM) data: GMI (%) = 3.31 + 0.02392 × mean glucose (mg/dL). It's very close to, but not identical to, the estimated-A1C formula shown above — GMI was derived from a newer, CGM-specific study population, while the classic eAG/A1C formula came from the original ADAG study using periodic blood draws. Neither replaces an actual lab A1C test.

Formulas used in this converter

  • mg/dL to mmol/L: divide by 18.0182 (based on the molar mass of glucose). 126 mg/dL = 7.0 mmol/L.
  • mmol/L to mg/dL: multiply by 18.0182. 5.5 mmol/L = 99 mg/dL.
  • A1C to estimated average glucose (eAG): eAG = 28.7 × A1C − 46.7, from the ADAG study used by the American Diabetes Association.
  • Average glucose to A1C: A1C = (eAG + 46.7) ÷ 28.7. An average of 154 mg/dL corresponds to an A1C of about 7.0%.
  • IFCC units: mmol/mol = (A1C − 2.15) × 10.929, so 7.0% equals 53 mmol/mol.
  • GMI for continuous glucose monitor data: 3.31 + 0.02392 × mean glucose.

A1C to average glucose chart

A1CeAG (mg/dL)eAG (mmol/L)
5%975.4
6%1267.0
7%1548.6
8%18310.2
9%21211.7
10%24013.3

Reference ranges

CategoryFasting glucoseA1C
Normalbelow 100 mg/dL (5.6 mmol/L)below 5.7%
Prediabetes100 to 125 mg/dL5.7% to 6.4%
Diabetes126 mg/dL (7.0 mmol/L) or higher6.5% or higher

The ADA's general A1C goal for many adults with diabetes is below 7%, but your doctor may set a different target.

Why estimated A1C and lab A1C can differ

A1C reflects glucose attached to red blood cells over roughly 2 to 3 months, weighted toward the most recent weeks. Anemia, recent blood loss, pregnancy, kidney disease and some hemoglobin variants can make lab A1C read higher or lower than your meter average suggests. A gap of 0.5 percentage points or more between GMI and lab A1C is common and worth discussing with your care team, not a sign that either number is wrong.

For related health numbers, see the glycemic load calculator, the BMI calculator and the macro calculator.