Power Outage Calculator

Size a backup battery or generator for your essential devices

Frequently Asked Questions

Add up the wattage of everything you want to keep running, multiply by the hours of outage you're planning for to get watt-hours (Wh) needed, then divide by your battery/inverter's efficiency (typically 85%) to get the required capacity, since some energy is lost in conversion.
For a generator, size it to your total running wattage (the sum of everything running at once) plus headroom for starting surge — motors and compressors (fridges, well pumps, AC) can draw 2-3x their running wattage for a second or two when starting. Add 20-30% headroom over your calculated total running wattage.
It varies widely: a phone charger might use 10-20W, a refrigerator 100-800W (cycling on and off, not continuous), a window AC unit 500-1500W, and a well pump 750-1500W. Check the device's nameplate or manual for its actual wattage rather than guessing.
Consumer power banks are usually rated in mAh at a nominal 3.7V per cell. To compare a power bank's mAh rating to the watt-hours you need, use: watt-hours = mAh ÷ 1000 × 3.7. This calculator converts your required watt-hours into an equivalent mAh figure for that comparison.

How backup power is sized

  • Total load (W) = the sum of the watts of every device you want to run
  • Energy needed (Wh) = total watts × outage hours
  • Battery capacity = energy ÷ 0.85, allowing for inverter losses
  • Power bank equivalent (mAh) = Wh ÷ 3.7 V × 1,000
  • Generator size = running watts × 1.25, rounded up

Example

A refrigerator (150 W), Wi-Fi router (10 W), LED lights (40 W) and phone charging (20 W) add up to 220 W. For a 6-hour outage that is 1,320 Wh, or about 1,550 Wh of battery after inverter losses, the size of a large portable power station. A generator would need about 300 running watts.

Typical device wattage

DeviceRunning wattsNotes
Refrigerator100 to 250runs about a third of the time; startup surge 2 to 3 times higher
Chest freezer50 to 100stays cold 24 to 48 hours if kept closed
Wi-Fi router and modem10 to 20
LED bulb8 to 12 each
Laptop50 to 100
CPAP machine30 to 60more with a heated humidifier
Sump pump (½ hp)about 800surge up to 2,000 or more
Space heater1,500drains batteries quickly

Make the estimate realistic

A refrigerator does not draw its rated watts continuously; it cycles on and off and uses roughly 1 to 2 kWh a day. Entering its running watts for the whole outage gives a safe upper estimate. Motors (fridges, pumps, well pumps) draw a short surge when starting, so a generator or inverter must handle that peak, not just the running total.

Battery or generator?

  • Portable power stations are silent and safe indoors, good for electronics, CPAP and short outages. Check the usable capacity in Wh and the continuous and surge watt ratings.
  • Gas generators run for days on fuel and handle large loads, but must run outdoors, at least 20 feet from doors and windows. Carbon monoxide from generators kills people every year; never run one in a garage.

To see what devices cost to run normally, use the electricity cost calculator or the appliance energy calculator. For long-term backup, the solar panel calculator estimates a system's output.